BSIA System Installation
Step 9: Configure System
34
Strata AirLink Installation Guide 5/00
Programming Sheets
Table 5
System Settings
Parameter
Description
Units/
Range
Suggested
Setting
Your
Setting
System ID
ID for the system (written on the
RWIU label).
1~5
Base Station 1 ID
ID of the first Base Station.
0~31
Base Station 2 ID
ID of the second Base Station.
0~31
Stop Ringing Time
Length of time the RWIU waits
after last detection of ring voltage
on a line before it stops the ring.
100 ms
1
1. For example, a setting of 2 means 2 x 100 ms or 200 ms.
45
Dial Tone Delay
2
2. The Dial Tone Delay eliminates the possibility of a user dialing before the office telephone system is ready.
Time delay between pressing
&$//
and outpulsing DTMF
tones.
100 ms
1
2
DTMF Cycle Duration
Duration of the full DTMF cycle
(length of tone plus length of
silence between tones) for dialing
and other telephone system
operations.
10 ms
3
3. For example, a setting of 2 means 2 x 10 ms or 20 ms.
20
DTMF Off Duration
Duration of silence between
DTMF tones.
10 ms
3
10
Hookflash Duration
Duration of the hookflash in
signaling the office telephone
system.
100 ms
1
5
FT Pause Duration
Duration of pause events in the
Feature Table.
100 ms
1
10
FT Inter-event Pause
Duration of pause between events
in the Feature Table.
100 ms
1
1
Second Base Station
Service Enabled
Enables service for a second
Base Station. TRUE if a second
Base Station is installed. FALSE if
only one Base Station is installed
or out of order.
NA
Summary of Contents for Strata AirLink
Page 6: ...Contents Chapter 5 Maintenance and Troubleshooting iv Strata AirLink Installation Guide 5 00 ...
Page 10: ...Introduction Related Documents Media viii Strata AirLink Installation Guide 5 00 ...
Page 28: ...Pre installation Step 10 Mount Base Stations 18 Strata AirLink Installation Guide 5 00 ...
Page 106: ...Maintenance and Troubleshooting Troubleshooting 96 Strata AirLink Installation Guide 5 00 ...