Maintenance and Troubleshooting
Troubleshooting
Strata AirLink Installation Guide 5/00
91
Replace Defective Handsets
Log Files
The Strata AirLink Manager creates log files that open in any text editor for viewing. If the log file
has blank lines when opened, Strata AirLink Manager is running in the background. Close the
software and re-open the log file.
Communication errors (PDQ Comm) occur in the log file when the BSIA is powered on. This has
no effect on performance.
If the log file has information about the boot software instead of the Base Station software after an
upgrade or when querying the software, try querying the BSIA software version before querying
the Base Station software.
1. Go to the Configure Window.
2. Pull down the Select
Database menu and click
User Database.
x
3. From the User Database
toolbar, click Get.
Current information displays.
4. Highlight the handset ID to
be replaced and delete the ID.
5. From the User Database
toolbar, click Send.
Strata AirLink Manager prompts for confirmation.
6. Click OK.
The new data is uploaded.
7. Input the original handset ID.
Important!
Enter the new SID and HID in the handset by
accessing System Configuration (
+
)&1
).
8. From the User Database
toolbar, click Send.
Strata AirLink Manager prompts for confirmation.
9. Click OK.
The data is uploaded.
10. Go off-hook and press
&$//
.
New ESN is locked into the BSIA.
3272
Summary of Contents for Strata AirLink
Page 6: ...Contents Chapter 5 Maintenance and Troubleshooting iv Strata AirLink Installation Guide 5 00 ...
Page 10: ...Introduction Related Documents Media viii Strata AirLink Installation Guide 5 00 ...
Page 28: ...Pre installation Step 10 Mount Base Stations 18 Strata AirLink Installation Guide 5 00 ...
Page 106: ...Maintenance and Troubleshooting Troubleshooting 96 Strata AirLink Installation Guide 5 00 ...