Pre-installation
Step 9: Use Stand-alone Base Station Test Stand
Strata AirLink Installation Guide 5/00
15
Substep D: Audio Coverage Test
Important!
Strata DK must recognize DTMF signaling, if you have a BSIA. Strata DK requires
a DTMF receiver PCB to support the RSTU ports.
1. Press
3:5
to turn on the handset.
2. Press
&$//
.
3. Listen for continuous tone while walking around the facility observing coverage area
boundaries.
4. Mark the floor plan where the continuous tone “warbles” (indicating the beginning of a
handoff overlap area) and where the continuous tone “breaks” or stops (indicating the end of
the coverage area).
5. Press
(1'
. The handset returns to idle.
Substep E: Perform Handset Bit Error Rate (BER) Test
1. Simulate real use rather than
trying to get the best readings
by:
♦
Perform tests in all
possible areas that users
may carry their
handsets.
♦
Remain in an area long
enough to get an
accurate reading. BER
readings can take a few
seconds to register. It is
recommended that you
stand still for an
accurate reading.
♦
Test specific Base
Stations. Handsets do
not perform handoff
during BER tests so that
you can test each Base
Station
2. In idle mode, press
.
3. Press
$%&
, then
&$//
.
B E R
M E A S U R E
1 2 : 1 5
Summary of Contents for Strata AirLink
Page 6: ...Contents Chapter 5 Maintenance and Troubleshooting iv Strata AirLink Installation Guide 5 00 ...
Page 10: ...Introduction Related Documents Media viii Strata AirLink Installation Guide 5 00 ...
Page 28: ...Pre installation Step 10 Mount Base Stations 18 Strata AirLink Installation Guide 5 00 ...
Page 106: ...Maintenance and Troubleshooting Troubleshooting 96 Strata AirLink Installation Guide 5 00 ...