Troubleshooting Procedures
TECRA M11/Satellite Pro S500M Series Maintenance Manual (960-813) [CONFIDENTIAL]
2-17
Main Battery
Error code Meaning
22h
Main battery discharge current is over 0.5A.
23h
Main battery charge current is over 4.3A.
24h
The compensation value of [0A] is not within the limits from design data (±
400mA).
25h
Main battery charge current is over 0.3A when the charging is off.
26h
Unusual voltage occurred during Main battery charge.
2nd Battery
Error code
Meaning
32h
Second battery discharge current is over 0.5A.
33h
Second battery charge current is over 2.7A.
34h
The compensation value of [0A] is not within the limits from design data (±
400mA)
35h
Second battery charge current is over 0.3A
36h
Unusual voltage occurred during Second battery charge.
S3V output
Error code Meaning
40h
S3V voltage is over 3.47V.
45h
S3Vvoltage is under 3.14V.
46h
S3V voltage is under 3.14V or less when the computer is booting up.
E5V output
Error code Meaning
50h
E5V voltage is over 6.00V.
51h
E5V voltage is under 4.50V when the computer is powered on.
52h
E5V voltage is under 4.50V when the computer is booting up.
54h
E5V voltage is under 4.50V when EV power is maintained.