7
OTHERS
OTHERS
Gas Leak Test
Test Operation
To switch the TEST RUN (COOL)
mode, press RESET button for
10 seconds. (The beeper will make
a short beep.)
Auto Restart Setting
The product was shipped with Auto Restart function in the off position.
Turn it on as required.
How to set the Auto Restart
Remote Control A-B Selection
PRESET
FAN
“B” Display
“00” Display
To separate using of remote control for each indoor unit in case of 2 air
conditioner are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHK] button on the Remote Control by the tip of the pencil.
“00” will be shown on the display.
4. Press [MODE] during pushing [CHK]. “B” will show on the display and “00”
will disappear and the air conditioner will turn OFF. The Remote Control B
is memorized.
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A have not “A” display.
3. Default setting of Remote Control from factory is A.
• When two indoor units are installed in the same room or adjacent two
rooms, if operating a unit, two units may receive the remote control signal
simultaneously and operate. In this case, the operation can be preserved
by setting either one remote control to B setting. (Both are set to A setting
in factory shipment.)
• The remote control signal is not received when the settings of indoor unit
and remote control are different.
• There is no relation between A setting/B setting and A room/B room when
connecting the piping and cables.
• Check the
fl
are nut connec-
tions for the gas leak with a
gas leak detector or soap
water.
This product is designed so that, after a power failure, it can restart automatically
in the same operating mode as before the power failure.
• Press and hold the RESET button for about 3 seconds. After 3 seconds, the
electronic beeper makes three short beeps to tell you the Auto Restart has
been selected.
• To cancel the Auto Restart, follow the steps described in the section Auto
Restart Function of the owner’s manual.
Stripping length of the connecting cable
Power source
50Hz, 220 – 240 V Single phase
60Hz, 220 – 230 V Single phase
Maximum running current
11A
Plug socket & fuse rating
25A
Power cord
H07RN-F or 245 IEC66 (2.0 mm
2
or more)
NOTE
: Connecting cable
• Wire type : More than H07RN-F or 245 IEC66
• Wrong wiring connection may cause some electrical parts burn out.
• Be sure to comply with local cords on running the wire from indoor unit
to outdoor unit (size of wire and wiring method, etc.).
• Every wire must be connected
fi
rmly.
• This installation fuse (25A) must be used for the power supply line of
this air conditioner.
• If incorrect or incomplete wiring is carried out, it will cause an ignition or
smoke.
• Prepare the power supply for exclusive use with the air conditioner.
• This product can be connected to the mains.
Connection to
fi
xed wiring: A switch which disconnects all poles and
has a contact separation of at least 3 mm must be incorporated in the
fi
xed wiring.
CAUTION
Check places for
the indoor unit.
Electric parts
cover
Check places for
the outdoor unit.
Valve cover
Information
0
1
0
1
0
1
0
1
30
30
40
40
L N
1 2 3
1
2
L
N
3
Connecting cable
Power cord
Earth line
Earth line
Connecting
cable
Terminal
block
Power
cord
RESET
Hi POWER FILTER PAP TIMER OPERATION
RESET button
1110251217-EN.indd 7
1110251217-EN.indd 7
2/3/10 10:46:51 AM