28
9
Combined Refrigerant Piping Systematic Drawings
Normal Operation
(Cooling mode)
P
ropeller fan
Check joint (Pd)
Check
valve
Check
valve
Check valve
Check
valve
Check valve
Check
valve
Accumulator
Check
joint (P
s)
Capillary
Capillary
Capillary
Capillary
Fixed-speed
Inverter
Compressor
Capillary
Sensor
(TE1)
Sensor (TS)
Sensor
(TK1)
Sensor
(TK2)
Sensor
(TK3)
Sensor
(TD1)
Sensor
(TD1)
Sensor
(TD2)
Strainer
Strainer
Strainer
Strainer
Strainer
Strainer
Strainer
Strainer
Air heat exchanger at outdoor side
Fan Motor
PMV (A)
PMV
PMV
PMV
Liquid
tank
Dryer
(x2)
Oil
separator
(Right side)
Air heat exchanger at outdoor side
Pulse motor valve B
(Cooling bypass)
(PMVB)
Solenoid valve
(SV2)
High-
pressure
sensor
Low
-
pressure
sensor
High- pressure SW
High- pressure SW
Solenoid valve
(SV3C)
Solenoid
valve
(SV3B)
Solenoid valve (SV3A)
Compressor case oil removal valve
Solenoid
valve
(SV42)
(Left side)
M
Service
valve
(gas side)
Oil tank
Packed
valve (oil
balancing
pipe)
Packed
valve
(liquid
side)
MM-
A0280HT
Master unit 1 (Inverter)
MM-
A0280HX
Slave unit 2 (Fixed-
speed)
MM-
A0280HX
Slave unit 3 (Fixed-
speed)
MM-
A0280HX
Slave unit 4 (Fixed-
speed)
(Indoor unit 1)
(Indoor unit 2)
Air heat
exchanger
at indoor
side
Evaporator
Evaporator
Evaporator
TC
1
TC
2
TC
1
TC
2
P
ressure
sensor
P
ressure
sensor
Check
joint
Check
joint
TA
(Ambient
sensor)
TA
(Ambient
sensor)
Strainer
(Indoor unit 3)
TC
1
TC
2
P
ressure
sensor
Check
joint
TA
(Ambient
sensor)
(Solid line) High-pressure gas or compressed liquid refrigerant
(Dotted line) Evaporating gas refrigerant (Low
-pressure gas)
P
ropeller fan
Check joint (Pd)
Check valve
Check
valve
Check
valve
Check valve
Check
valve
Check valve
Check
valve
Accumulator
Check
joint (P
s)
Capillary
Capillary
Capillary
Capillary
Capillary
Fixed-speed
Fixed-speed
Compressor
Capillary
Sensor
(TE1)
Sensor (TS)
Sensor
(TK1)
Sensor
(TK2)
Sensor
(TK3)
Sensor
(TD2)
Strainer
Strainer
Fan Motor
PMV (A)
Liquid
tank
Dryer
(x2)
Oil
separator
Condenser
4-
W
ay valve
4-
W
ay valve
Condenser
Pulse motor valve B
(Cooling bypass)
(PMVB)
Solenoid valve
(SV2)
High-
pressure
sensor
Low
-
pressure
sensor
High- pressure SW
High- pressure SW
Solenoid valve
(SV3C)
Solenoid
valve
(SV3B)
Solenoid valve (SV3A)
Compressor case oil removal valve
Solenoid
valve
(SV41)
Solenoid
valve
(SV42)
M
Service
valve
(gas side)
Oil tank
Packed
valve (oil
balancing
pipe)
Packed
valve
(liquid
side)
HP
HP
HP
HP
Service valve (gas side)
Packed valve (oil balancing pipe)
Packed valve (liquid side)
Service valve (gas side)
Packed valve (oil balancing pipe)
Packed valve (liquid side)
Strainer
Strainer
Summary of Contents for MM-A0160HX
Page 1: ...Service Manual Air Conditioner Multi Split Type System Modular Multi System HFCR407C A90 0130 ...
Page 2: ......
Page 133: ...134 20 Additional Literature and Contacts ...
Page 134: ...135 20 Additional Literature and Contacts ...
Page 135: ...TOSHIBA AIR CONDITIONING www toshiba aircon co uk MADE IN UK A90 0130 Revised April 2001 ...