Alarm Terminals
You can connect a variety of sensors to the camera by using alarm terminals.
See following table for functions of each terminal.
■ Connecting External Alarm Devices to the Alarm Input/Output
Terminals
・ Be sure to connect cables of external alarm devices before connecting
AC adaptor cable and LAN cable to the camera.
・ When you place IK-WB11A outside, be sure to waterproof the devices and
cables just like the power cord and LAN cable by using conduit pipes
or the like.
ALARM OUT
Alarm output terminal
ALARM IN
Alarm input terminal
GND
Name
ALARM IN
ALARM OUT
GND
Function
Alarm Input
Alarm Output
GND
Description
・Inputs External Alarm signal.
You can choose the type of input signal:
Normal Opened (NO) or Normal Closed (NC).
Connect a sensor or other devices to the
camera.
・Outputs open corrector.
Max.DC 24V, 50mA.
Output holding time follows the those of
Alarm Settings/Alarm Output. (→page 94)
GND for a signal