230
⎯
6
F
2
S
0
8
3
5
Signal list
161 TDBL1
TDBL1 timer output
162 TLBD1
TLBD1 timer output
163 TSYN1
TSYN1 timer output
164 TDBL2
TDBL2 timer output
165 TLBD2
TLBD2 timer output
166 TSYN2
TSYN2 timer output
167 REC-READY1
ARC ready signal in leader CB autoreclose
168 REC-READY2
ARC ready signal in follower CB autoreclose
169 BRIDGE1
Bridge condition in leader CB autoreclose
170 BRIDGE2
Bridge condition in follower CB autoreclose
171 IN-PROG1
ARC in-progress in leader CB autoreclose
172 IN-PROG2
ARC in-progress in follower CB autoreclose
173 SPAR1
Single-phase autoreclose signal for leader CB
174 SPAR2
Single-phase autoreclose signal for follower CB
175 TPAR1
Three-phase autoreclose signal for leader CB
176 TPAR2
Three-phase autoreclose signal for follower CB
177 ARC1
Autoreclose command for CB1
178 ARC2
Autoreclose command for CB2
179 94TT1
Discrepancy trip signal in leader CB autoreclose
180 94TT2
Discrepancy trip signal in follower CB ARC
181 FT1
Final trip of leader CB
182 FT2
Final trip of center CB
183 MPAR1
Multi-phase auoteclosing signal in leader CB ARC
184 TEVLV
TEVLV timer output
185 MPAR2
Multi-phase auoteclosing signal in follower CB ARC
186 TP-MPH
Multi-phase trip
187 TP-1PH
single phase trip
188 TP-2PH
two or more phase trip
189 TSPR3
Dead time count up signal in follower CB MPAR
190 TTPR3
Dead time count up signal in follower CB MPAR
191 READY
Local terminal ready
192 REM1 READY
Terminal 1 ready
193 REM2 READY
Terminal 2 ready
194 MASTER
Being set to master terminal
195 SLAVE
Being set to slave terminal
196 FG
Trigger signal for end-to-end synchronized test
197 85R1.REM1
Transfer trip command 1 receiving from terminal 1
198 85R2.REM1
Transfer trip command 2 receiving from terminal 1
199 REC-BLK1
Autoreclose blocked at terminal 1
200 TFC ON1
TFC scheme ON setting between remote terminal 1
201 LOCAL TEST1
Terminal 1 "under local test"
202 85R1.REM2
Transfer trip command 1 receiving from terminal 2
203 85R2.REM2
Transfer trip command 2 receiving from terminal 2
204 REC-BLK2
Autoreclose blocked at terminal 2
205 TFC ON2
TFC scheme ON setting between remote terminal 2
206 LOCAL TEST2
Terminal 2 "under local test"
207 REM1 IN SRV
Terminal 1 "in-service"
208 REM1 OFF SRV
Terminal 1 "out-of-service"
209 REM1 NON USE
Terminal 1 "not used"
210 REM2 IN SRV
Terminal 2 "in-service"
211 REM2 OFF SRV
Terminal 2 "out-of-service"
212 REM2 NON USE
Terminal 2 "not used"
213 UNREADY1
Terminal 1 communication not ready
214 CFSV1
Terminal 1 CFSV
215 SPSV1
Sampling synchronization with terminal 1 failure signal
216 TX LEVEL1
Terminal 1 drop of transmission signal level
217 RX LEVEL1
Terminal 1 drop of receiving signal level
218 CLK1
Terminal 1 interrupt of clock signal
219 UNREADY2
Terminal 2 communication not ready
220 CFSV2
Terminal 2 CFSV
221 SPSV2
Sampling synchronization with terminal 2 failure signal
222 TX LEVEL2
Terminal 2 drop of transmission signal level
223 RX LEVEL2
Terminal 2 drop of receiving signal level
224 CLK2
Terminal 2 interrupt of clock signal
225 COMM1 FAIL
Communication with terminal 1 failure signal
226 COMM2 FAIL
Communication with terminal 2 failure signal
227 TRANSFER
Transfer trip receive
228 RDIF-R1 OR
RDIF1 (Remote differential trip received from remote-1)
229 RDIF-R2 OR
RDIF2 (Remote differential trip received from remote-2)
230 CFSV1/2-L
CFSV1/2-L (Communication fail (236+238))
231 RLY FAIL
Relay failure
232 RLY OP BLK
Relay output block
233 AMF OFF
A.M.F disabling signal
234 O/P CIR. SV
False operation of tripping output circuit
235 LSSV
DS failure signal
236 CFSV1-L
CFSV1-L (Communication with term.1 fail detected by local relay)
237 CFSV1-R
CFSV1-R (Communication with term.1 fail detected by remote relay)
238 CFSV2-L
CFSV2-L (Communication with term.2 fail detected by local relay)
239 CFSV2-R
CFSV2-R (Communication with term.2 fail detected by remote relay)
240
No.
Signal Name
Contents
Summary of Contents for GRL100-101A
Page 223: ... 222 6 F 2 S 0 8 3 5 ...
Page 228: ... 227 6 F 2 S 0 8 3 5 Appendix B Signal List ...
Page 256: ... 255 6 F 2 S 0 8 3 5 Appendix C Variable Timer List ...
Page 258: ... 257 6 F 2 S 0 8 3 5 Appendix D Binary Output Default Setting List ...
Page 269: ... 268 6 F 2 S 0 8 3 5 ...
Page 270: ... 269 6 F 2 S 0 8 3 5 Appendix E Details of Relay Menu ...
Page 279: ... 278 6 F 2 S 0 8 3 5 ...
Page 288: ... 287 6 F 2 S 0 8 3 5 Appendix G Typical External Connection ...
Page 326: ... 325 6 F 2 S 0 8 3 5 Appendix J Return Repair Form ...
Page 330: ... 329 6 F 2 S 0 8 3 5 Customer Name Company Name Address Telephone No Facsimile No Signature ...
Page 331: ... 330 6 F 2 S 0 8 3 5 ...
Page 332: ... 331 6 F 2 S 0 8 3 5 Appendix K Technical Data ...
Page 343: ... 342 6 F 2 S 0 8 3 5 ...
Page 344: ... 343 6 F 2 S 0 8 3 5 Appendix L Symbols Used in Scheme Logic ...
Page 347: ... 346 6 F 2 S 0 8 3 5 ...
Page 348: ... 347 6 F 2 S 0 8 3 5 Appendix M Multi phase Autoreclose ...
Page 351: ... 350 6 F 2 S 0 8 3 5 ...
Page 352: ... 351 6 F 2 S 0 8 3 5 Appendix N Data Transmission Format ...
Page 358: ... 357 6 F 2 S 0 8 3 5 Appendix O Example of DIF and DIFG Setting ...
Page 364: ... 363 6 F 2 S 0 8 3 5 Appendix Q IEC60870 5 103 Interoperability ...
Page 377: ... 376 6 F 2 S 0 8 3 5 ...
Page 378: ... 377 6 F 2 S 0 8 3 5 Appendix R Failed Module Tracing and Replacement ...
Page 384: ... 383 6 F 2 S 0 8 3 5 Appendix S PLC Setting Sample ...
Page 386: ... 385 6 F 2 S 0 8 3 5 Appendix T Ordering ...
Page 392: ......