Enter 1 and press the ENTER key to operate the output relays forcibly.
•
After completing the entries, press the END key. Then the LCD displays the screen shown
below.
/ 3
B O
K e e p p r e s s i n
o
t
1
g
o p e r a t e .
P r e s s
C A N C E L
t o
c a n c e l .
•
Keep pressing the 1 key to operate the assigned output relays.
•
Release pressing the 1 key to reset the operation.
Caution
: In case of relay models with fault detector, FD module BO also operates when IO#1
module BO is forcibly operated.
•
Press
the CANCEL key to return to the upper screen.
4.2.7.3 Timer
The pick-up or drop-off delay time of the variable timer used in the scheme logic can be
measured with monitoring jacks A and B. Monitoring jacks A and B are used to observe the
input signal and output signal to the timer, respectively.
•
Press 3(= Timer) on the "Test menu" screen to display the "Timer" screen.
/ 2
T i m e r
1 /
1
T i m e r (
1 -
4 8 ) :
1
•
Enter the number corresponding to the timer to be observed and press the ENTER key. The
timers and related numbers are listed in Appendix C.
•
Press
the END key to display the following screen.
Summary of Contents for GRL100-101A
Page 223: ... 222 6 F 2 S 0 8 3 5 ...
Page 228: ... 227 6 F 2 S 0 8 3 5 Appendix B Signal List ...
Page 256: ... 255 6 F 2 S 0 8 3 5 Appendix C Variable Timer List ...
Page 258: ... 257 6 F 2 S 0 8 3 5 Appendix D Binary Output Default Setting List ...
Page 269: ... 268 6 F 2 S 0 8 3 5 ...
Page 270: ... 269 6 F 2 S 0 8 3 5 Appendix E Details of Relay Menu ...
Page 279: ... 278 6 F 2 S 0 8 3 5 ...
Page 288: ... 287 6 F 2 S 0 8 3 5 Appendix G Typical External Connection ...
Page 326: ... 325 6 F 2 S 0 8 3 5 Appendix J Return Repair Form ...
Page 330: ... 329 6 F 2 S 0 8 3 5 Customer Name Company Name Address Telephone No Facsimile No Signature ...
Page 331: ... 330 6 F 2 S 0 8 3 5 ...
Page 332: ... 331 6 F 2 S 0 8 3 5 Appendix K Technical Data ...
Page 343: ... 342 6 F 2 S 0 8 3 5 ...
Page 344: ... 343 6 F 2 S 0 8 3 5 Appendix L Symbols Used in Scheme Logic ...
Page 347: ... 346 6 F 2 S 0 8 3 5 ...
Page 348: ... 347 6 F 2 S 0 8 3 5 Appendix M Multi phase Autoreclose ...
Page 351: ... 350 6 F 2 S 0 8 3 5 ...
Page 352: ... 351 6 F 2 S 0 8 3 5 Appendix N Data Transmission Format ...
Page 358: ... 357 6 F 2 S 0 8 3 5 Appendix O Example of DIF and DIFG Setting ...
Page 364: ... 363 6 F 2 S 0 8 3 5 Appendix Q IEC60870 5 103 Interoperability ...
Page 377: ... 376 6 F 2 S 0 8 3 5 ...
Page 378: ... 377 6 F 2 S 0 8 3 5 Appendix R Failed Module Tracing and Replacement ...
Page 384: ... 383 6 F 2 S 0 8 3 5 Appendix S PLC Setting Sample ...
Page 386: ... 385 6 F 2 S 0 8 3 5 Appendix T Ordering ...
Page 392: ......