23
5-2. Outdoor Unit (Single phase Type)
HWS-803H-E, HWS-1103H-E, HWS-1403H-E
Control board
(Blue)
(
White
)
HMS-1103,
1403H-E only
(
White
)
(
White
)
Upper
(
White
)
Operating
power
4-way
valve
coil
Reactor
220-230V
50Hz
4F
20SF
Earth screw
Earth screw
Earth screw
Hydro unit
Outdoor unit
Power supply
single phase
(
Yellow
)
(
White
)
(
White
)
(
Yellow
)
(
White
)
(
White
)(
White
)(
White
)
(
White
)
WR
B
White
Red
G
RW
B
External
input
Symbol
Item name
Compressor
Fan motor
Pulse motor valve coil
Discharge temperature sonsor
Suction temperature sensor
Heat exchange sensor 1
Heat exchange sensor 2
Outdoor temperature sensor
Linetilter
4-way valve coil
Compressor case thermostat
Fuse 25 A, 250 VAC
Fuse 10A, 250 VAC
1. indicates a terminal plate. The number inside indicates the terminal number.
2. The double-dashed line indicates a local wiring while the dashed line indicates
an optional accessory or service wiring.
3. indicates a printed board.
4. For the hydro unit circuit, see the hydro unit wiring diagram.