128
1-6. SW13 (System switching 3)
2. Hydro unit Function Code Setting
2-1. How to set function code
<Procedure> Perform the following when no operation is in progress.
1
Press the SET
and TEST
and SELECT
buttons at the same time for 4 seconds or longer.
(See display
)
2
Specify CODE NO. (FC) with the TEMP.
button
for temperature setting.
3
Select a setting data with the TIME
button for timer
setting.
The value in the DATA item changes.
4
Press the SET
button. (If
lights, the status is
confirmed)
To change the item to be set, go to
2
.
5
Pressing the TEST
button moves the unit to the normal
stop state.
2-2. How to set remote controller function code
This operation can set the start and end time of the night time low noise, anti bacteria, night set back, or other
functions.
<Procedure> Perform the following when no operation is in progress.
1
Press the TEST
and CL
and TEMP.
buttons at
the same time for 4 seconds or longer. (See display
)
appears on the left.
2
Specify CODE NO. (FC) with the TEMP.
button
for temperature setting.
3
Select a setting data with the TIME
button for timer
setting.
The value in the DATA item changes.
4
Press the SET
button.(If the blinking changes to lit, the
status is normal)
To change the item to be set, go to
2
.
5
Pressing the TEST
button moves the unit to the normal
stop state.
SW13
Switching details
Factory default
Remarks
13_1
3WV SPST/SPSD Specification switching
SPST
OFF
13_2
Boiler output enabled
No
OFF
13_3
Auto Restart of power outage
Yes
OFF
13_4
–
–
OFF
2
3
4
5
1
2
3
4
1
5