184
5
Interface board
(Control board)
MCC-1599
1. Detachment
1) Carry out the operation in 1. of 1), 1. of 3) above.
2) Remove lead wires and connectors to other
components from the interface board
(control board).
CN01 : Indoor/Outdoor connection terminal
(5P: White)
CN02 : Power relay (3P: Red)
CN600 : TS sensor (3P: White, tube: Gray)
CN601 : TE sensor (2P: Green, tube: Blue)
CN602 : TO sensor (2P: Yellow, tube: Black)
CN603 : TD sensor (3P: White, tube: Red)
CN604 : TL sensor (2P: White, tube: White)
CN608 : Connection with noise filter board
(2P: White)
CN609: Case thermo. (2P :Blue)
CN690 : High pressure switch (3P: Green)
CN700 : 4-way coil (3P: Yellow)
CN708 : Magnet switch (3P: Blue)
CN710 : PMV coil (6P: White)
CN802 : Connection with Fan IPDU board
(5P: white)
* Remove connectors after unlocking housing
section
3) Remove the claws of the supports (4 positions)
fixing the board and remove the interface board
(Control board).
2. Attachment
1) Mount the interface board (Control board).
2) Mount the individual components in the opposite
procedure to that during detachment.
No.
Part name
Procedure
Remarks
Support (4 positions)
Statue of control board when removed
Interface board
(Control board)
Summary of Contents for ESTIA HWS-1501CSHM3-E
Page 196: ...195 220 223 235 234 222 225 226 231 232 229 228 235 233 230 221 224 227 ...
Page 210: ...209 ...
Page 211: ...210 ...
Page 212: ......