March 2005 © TOSHIBA TEC
e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 39
2
2.2.3
Test print mode (test mode 04)
<Operation procedure>
Notes:
1. When an error occurs, it is indicated on the panel, but the recovery operation is not per-
formed. Turn OFF the power and then back ON to clear the error.
2. During test printing, the [CLEAR] button is disabled when “Wait adding toner” is displayed.
The embedded test pattern can be printed out by keying in the following codes in the test print mode
(04).
Code
Types of test pattern
Remarks
111
Primary scanning direction 33 gradation steps
Error diffusion
113
Secondary scanning direction 33 gradation steps
Error diffusion / gamma adjustment pattern
142
Grid pattern
Pattern width: 2 dots, Pitch: 10 mm
182
Secondary scanning direction 33 gradation steps
(dither)
Gamma adjustment pattern
184
Secondary scanning direction 33 gradation steps
and dither process check pattern
Gamma adjustment check pattern
[0][4]
[POWER]
[POWER] OFF/ON
(Exit)
(Code)
[START]
[CLEAR]
Operation
Continuous
Test Printing
Summary of Contents for E-STUDIO520
Page 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Page 6: ......
Page 12: ......
Page 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Page 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Page 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Page 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Page 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Page 591: ......
Page 592: ......