3) Moire/lack of sharpness
Fig.5-3
Moire
Lack of sharpness
Defective area
Step
Check items
Prescription
Density reproduction
1
Check the reproduction of the image
density.
Adjust the density.
Parameter adjustment
value
2
Check the image processing param-
eters.
Check the adjustment value for
sharpness.
Printer section
3
Check test print image (04-113).
When defects occur, perform the cor-
responding troubleshooting proce-
dure.
Defective area
Step
Check items
Prescription
Density reproduction
1
Check the reproduction of the image
density.
Adjust the density.
Parameter adjustment
value
2
Check the image processing param-
eters.
Check the adjustment value for
sharpness.
Printer section
3
Check test print image (04-113).
When defects occur, perform the cor-
responding troubleshooting proce-
dure.
4
Check the image processing param-
eters.
Check the encircled areas A and B in
the image, and change the sharp-
ness intensity in the sharpness
adjustment mode.
Feeding direction
A
B
Summary of Contents for E-STUDIO520
Page 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Page 6: ......
Page 12: ......
Page 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Page 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Page 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Page 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Page 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Page 591: ......
Page 592: ......