March 2005 © TOSHIBA TEC
e-STUDIO520/600/720/850 ADJUSTMENT
3 - 55
3
(3)
Close the RADF to check that the positioning
pins fit smoothly into the holes on the RADF.
If they do not, adjust them according to the
following procedure.
Fig.3-51
(4)
Loosen the stepped screw 1 turn and 2
screws on the adjustment plate a half turn
(status of temporary fixing).
Fig.3-52
(5)
Remove the stepped screw at the rear of
right-hand hinge.
Fig.3-53
2 screws: Half turn
Stepped screw: 1 turn