e-STUDIO520/600/720/850 TROUBLESHOOTING
March 2005 © TOSHIBA TEC
5 - 124
5.2
Troubleshooting for the Image
If any abnormal image occurs in the test copying, perform trouble shooting for the image.
1) Abnormality of image density / Gray balance
Fig.5-1
Defective area
Step
Check items
Prescription
Density/Gray balance
1
Check the density/gray balance.
Adjust the density.
Printer section
2
Check test print image (04-113).
Go to step 4 if there is any problem
on image.
Scanner
3
Are the original glass, mirrors and
lens dirty?
Clean them.
Printed image
4
Is the image faded?
Perform troubleshooting for faded
image.
5
Is background fogging occurring?
Perform troubleshooting for back-
ground fogging.
6
Is there a blotch on the image?
Perform troubleshooting for blotched
image.
7
Is the image transferred normally?
Perform troubleshooting for abnor-
mal transfer.
Feeding direction
Image density
Gray balance