e-STUDIO520/600/720/850 TROUBLESHOOTING
March 2005 © TOSHIBA TEC
5 - 126
Note:
Note:
1. Toner density correcting method
Change the setting value 'Toner density life correction setting (08-414)' (6 is the default setting.)
0: Appox. 0.75% lower than the current value
1: Appox. 0.50% lower than the current value
2: Appox. 0.25% lower than the current value
3: The current value (Default setting)
4: Appox. 0.15% higher than the current value
5: Appox. 0.25% higher than the current value
6: Appox. 0.50% higher than the current value
7: Appox. 0.75% higher than the current value
<Caution for correction>
When increasing or decreasing the toner density too much, the image may become poor or the
life of developer material, cleaner, photoconductive drum and fuser unit, etc. may shorten. There-
fore it is not recommended to correct (to shift) the toner density basically. If it is shifted, make
sure that the image may be improper in a few minutes after shifting.
Main charger output
8
Is the setting value proper?
Is the main charger output normal?
Replace the high-voltage transformer
with a new one and print out a test
chart.
If any abnormal image appears,
check the harness connection
between the LGC board and the
high-voltage transformer, power sup-
ply and stain on the main charger
wire.
Developer unit
9
Is the contact between the drum and
developer material normal?
Replace the high-voltage transformer
with a new one and print out a test
chart.
If any abnormal image appears,
check the harness connection
between the LGC board and the
high-voltage transformer, power sup-
ply and stain on the main charger
wire.
Developer bias output
10
Is the setting value proper?
Is the developer bias output normal?
If the setting value is out of specifica-
tion, adjust it.
If the output is not normal, check the
circuits. (Note 1)
Increasing toner density
11
Is the Auto-toner sensor connected
correctly?
Check the connection of the connec-
tor of the Auto-toner sensor.
12
Is the toner density high?
Adjust the toner density.
(Note 2: See the toner density cor-
recting method.)
Image quality sensor/
Surface potential sensor
13
Are the image quality sensor and the
surface potential sensor normal?
Check the performance of the image
quality sensor and the surface poten-
tial sensor. (See the troubleshooting
related with the image quality con-
trol.)
Drum cleaning blade
14
Is the drum cleaned properly?
(See the troubleshooting for the poor
cleaning.)
Defective area
Step
Check items
Prescription
Summary of Contents for E-STUDIO520
Page 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Page 6: ......
Page 12: ......
Page 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Page 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Page 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Page 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Page 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Page 591: ......
Page 592: ......