e-STUDIO520/600/720/850 ADJUSTMENT
March 2005 © TOSHIBA TEC
3 - 20
[F]
Top margin
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
!
(Adjustment Mode)
(2)
Open the RADF.
(3)
Press [FAX] to make a copy at the mode of A3/LD, 100%, Text/Photo and the 2nd/4th drawer.
(4)
Measure the blank area E at the leading edge of the copied image.
(5)
Check if the blank area E is within the range of 3 ± 0.5 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode)
!
(Key in the code [430])
!
[START]
!
(Key in a value (acceptable values: 0 to 255))
!
Press the [ENTER] or the [INTERRUPT] button (stored in memory).
!
(“100% A” is displayed.)
*
The larger the adjustment value is, the wider the blank area becomes (approx. 0.04 mm/
step).
Fig.3-20
E