e-STUDIO520/600/720/850 TROUBLESHOOTING
5 - 41
5
[E870]
RADF open jam
Is the connector CN11 on the ADF board disconnected?
!
YES
"
Connect the connector.
NO
Is the harness between the ADF board and RADF open/close sensor open-circuited?
!
YES
"
Replace the harness.
NO
Is the RADF open/close sensor working improperly?
!
YES
"
Replace the RADF open/close sensor.
NO
Is the harness between the ADF board and APS operation sensor open-circuited?
!
YES
"
Replace the harness.
NO
Is the APS operation sensor working improperly?
!
YES
"
Replace the APS operation sensor.
NO
Replace the ADF board.