March 2005 © TOSHIBA TEC
e-STUDIO520/600/720/850 TROUBLESHOOTING
5 - 145
5
18)Image dislocation in feeding direction
Fig.5-18
Defective area
Step
Check items
Prescription
Scanner/Printer adjust-
ment
1
Have the printed images been dislo-
cated in the same manner?
Adjust the position of the leading
edge of paper in the Adjustment
Mode.
Registration roller
2
Is the registration roller dirty, or the
spring detached?
Clean the registration roller with alco-
hol.
Securely attach the springs.
3
Is the registration roller working prop-
erly?
Adjust or replace the gears if they are
not engaged properly.
Feed clutch
4
Is the feed clutch working properly?
Check the circuit or feed clutch, and
replace them if necessary.
Pre-registration guide
5
Is the pre-registration guide installed
properly?
Install the guide properly.
Feeding direction