e-STUDIO520/600/720/850 DATA CLONING with USB STORAGE DEVICE
March 2005 © TOSHIBA TEC
9 - 20
[C] Confirmation of the error
"Back Up ERROR X" (X: Error number) is displayed at the top of the LCD screen when the data have
not been properly backed up / restored. In this case, turn the power OFF and then check the following
items. After confirming and solving the problem, back up / restore the data again from the beginning.
•
Does the USB storage device meet the conditions being used for this cloning?
•
Is the updated program file written on the USB storage device properly?
•
Is the USB storage device installed properly?
•
Is the USB storage device or the equipment damaged?
Fig.9-29
Error number
Error content
ERROR 1
Copy error
ERROR 2
I/F error
ERROR 3
USB memory full error
ERROR 4
Working folder error
ERROR 5
File not found error
ERROR 6
Security error
ERROR 7
Checksum error
ERROR 8
Model check error
ERROR 9
Version check error
ERROR 10
Destination check error
ERROR 11
Serial number check error
05/11
Summary of Contents for E-STUDIO520
Page 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Page 6: ......
Page 12: ......
Page 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Page 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Page 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Page 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Page 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Page 591: ......
Page 592: ......