e-STUDIO520/600/720/850 ADJUSTMENT
March 2005 © TOSHIBA TEC
3 - 18
[D]
Reproduction ratio adjustment of the secondary scanning direction
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
!
(Adjustment Mode)
(2)
Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3)
Press [COPY] to make a copy at the mode of A3 (LD), 100% and the 2nd/4th drawer.
(4)
Measure the distance C from 10 mm to 210 mm of the copied image of the ruler.
(5)
Check if the distance C is within the range of 200±0.5 mm.
(6)
If not, use the following procedure to change values and repeat steps (3) to (5) above.
(Adjustment Mode)
!
(Key in the code [340])
!
[START]
!
(Key in a value (acceptable values: 0 to 255))
!
Press the [ENTER] or the [INTERRUPT] button (stored in memory).
!
(“100% A” is displayed.)
*
The smaller the adjustment value is, the lower the reproduction ratio becomes (0.46 mm/
step).
Fig.3-18
200
250
300
350
400
50
100
150
C
Feeding direction
Copied image of the ruler
Summary of Contents for E-STUDIO520
Page 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Page 6: ......
Page 12: ......
Page 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Page 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Page 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Page 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Page 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Page 591: ......
Page 592: ......