March 2005 © TOSHIBA TEC
e-STUDIO520/600/720/850 ADJUSTMENT
3 - 63
3
[B] Small original exit solenoid
<Procedure>
[C] Large original exit solenoid
<Adjustment procedure>
(1)
Put the end faces of the bracket and solenoid
together.
(2)
When the small original exit flapper is not
pulled out completely, loosen the screws and
then shift the solenoid upward.
(3)
When the small original exit flapper is pulled
out completely, tighten and fix the screws
Fig.3-70
(1)
Put the end faces of the bracket and solenoid
together.
(2)
When the large original exit flapper is not
pulled out completely, loosen the screw and
then shift the solenoid upward.
(3)
When the large original exit flapper is pulled
out completely, tighten and fix the screw.
Fig.3-71
Ends faced-up
Ends faced-up