e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
March 2005 © TOSHIBA TEC
2 - 10
C411
Fuser unit related
service call
Thermistor/heater abnormality at power-ON: Thermistor
abnormality is detected at power-ON or the fuser roller
temperature does not rise within a specified period of
time after power-ON.
Ch.5.1.8
C412
Thermistor/heater abnormality at power-ON: Thermistor
abnormality is detected at power-ON or the fuser roller
temperature does not rise within a specified period of
time after power-ON.
Ch.5.1.8
C443
Heater abnormality after abnormality judgment (not
reaching to intermediate temperature)
Ch.5.1.8
C445
Heater abnormality after abnormality judgment (pre-run-
ning end temperature abnormality)
Ch.5.1.8
C446
Heater abnormality after abnormality judgment (pre-run-
ning end temperature abnormality)
Ch.5.1.8
C447
Heater abnormality after abnormality judgment (tempera-
ture abnormality at ready status)
Ch.5.1.8
C449
Heater abnormality after abnormality judgment (overheat-
ing)
Ch.5.1.8
C465
Pressure roller thermistor abnormality after entering
ready status (pre-running end temperature abnormality)
Ch.5.1.8
C466
Pressure roller thermistor abnormality after entering
ready status (pre-running end temperature abnormality)
Ch.5.1.8
C467
Pressure roller thermistor abnormality after entering
ready status (temperature abnormality at ready status)
Ch.5.1.8
C468
Pressure roller thermistor abnormality after entering
ready status (overheating)
Ch.5.1.8
C471
IH power voltage abnormality or IH initial abnormality
(IH board initial abnormality)
Ch.5.1.8
C472
IH power voltage abnormality (power supply abnormality)
Ch.5.1.8
C473
IH power voltage abnormality (power voltage upper limit
abnormality)
Ch.5.1.8
C474
IH power voltage abnormality (power voltage lower limit
abnormality)
Ch.5.1.8
C475
IH power voltage abnormality (power supply abnormality
when door is opened)
Ch.5.1.8
C480
IH abnormality
Ch.5.1.8
C481
IGBT abnormality
Ch.5.1.8
C490
IH control circuit abnormality or IH coil abnormality: The
IH control circuit is under abnormal conditions, or the IH
coil is broken or has a short-circuit.
Ch.5.1.8
C4A0
End of cleaning web
Ch.5.1.8
C4B0
Fuser unit counter abnormality
Ch.5.1.8
C550
Optional communi-
cation related ser-
vice call
RADF interface error: Communication error has occurred
between the RADF and the scanner.
Ch.5.1.9
C560
Communication error between Engine-CPU and PFC
Ch.5.1.9
C570
Communication error between Engine-CPU and IPC
board
Ch.5.1.9
C580
Communication error between IPC board and Finisher
Ch.5.1.9
C590
Communication error between Engine-CPU and Laser-
CPU
Ch.5.1.9
Error code
Classification
Contents
Troubleshooting
Summary of Contents for E-STUDIO520
Page 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Page 6: ......
Page 12: ......
Page 200: ...e STUDIO520 600 720 850 ERROR CODE AND SELF DIAGNOSTIC MODE March 2005 TOSHIBA TEC 2 176 ...
Page 288: ...e STUDIO520 600 720 850 ADJUSTMENT March 2005 TOSHIBA TEC 3 88 ...
Page 540: ...e STUDIO520 600 720 850 POWER SUPPLY UNIT March 2005 TOSHIBA TEC 7 6 ...
Page 586: ...e STUDIO520 600 720 850 DATA CLONING with USB STORAGE DEVICE March 2005 TOSHIBA TEC 9 22 ...
Page 588: ...e STUDIO520 600 720 850 WIRE HARNESS CONNECTION DIAGRAMS March 2005 TOSHIBA TEC 10 2 ...
Page 591: ......
Page 592: ......