112
3. Parameter settings to be cleared and the initial values set after parameter clear
Settings printed on the maintenance counter/parameter setting data printout
<<ADJUST>>
Item
Description
Initial value
[PC] / [KEY]
FEED
Feed amount fine adjustment value
[PC] +0.0mm [KEY] +0.0mm
CUT
Cut position/Strip position fine adjustment
value
[PC] +0.0mm [KEY] +0.0mm
BACK
Reverse feed amount fine adjustment
value
[PC] +0.0mm [KEY] +0.0mm
TONE(T)
Print tone fine adjustment value (Thermal
transfer)
[PC] +0step
[KEY] +0step
TONE(D)
Print tone fine adjustment value (Direct
thermal)
[PC] +0step
[KEY] +0step
RIBBON TORQUE NORM
RBN(FW)
Ribbon
motor
drive
voltage
fine
adjustment (Take-up side)
[PC] +0step
[KEY] +0step
RBN(BK)
Ribbon
motor
drive
voltage
fine
adjustment (Supply side)
[PC] +0step
[KEY] +5step
RIBBON TORQUE LOW
RBN(FW)
Ribbon
motor
drive
voltage
fine
adjustment (Take-up side)
[PC] +0step
[KEY] +0step
RBN(BK)
Ribbon
motor
drive
voltage
fine
adjustment (Supply side)
[PC] +0step
[KEY] +5step
RIBBON WIDTH
Ribbon width (only B-EX6T1/T3)
“6
X ADJ.
X-coordinate fine adjustment value
+0.0mm
THRESHOLD(R)
Manual threshold fine adjustment for
reflective sensor
1.0V
THRESHOLD(T)
Manual threshold fine adjustment for
transmissive sensor
1.4V
<< PARAMETER SETTINGS>>
Item
Description
Initial value
MEDIA LOAD
Media feed to the print
start position
B-EX6T1/T3 OFF
B-EX4T1
ON
MOVE TO TEAROFF
Auto feed to the cut/strip
position after printing
QM TYPE
CN TYPE
OFF
JA TYPE
When the cutter installed: ON
When cutter not installed: OFF
Media stop position fine adjustment value +0.0mm
Feed mode
QM TYPE
CN TYPE
MODE1
JA TYPE
When
the
cutter
installed:
MODE2
When
cutter
not
installed:
MODE1
HEAD UP CUT/RWD
Whether to enable the head-up function
during cut issue or use the Rewinder
OFF