5. SYSTEM MODE
EO18-33027
5.11 RFID Module Setting
5-98
5.11.5 OTHER
The following information related RFID is displayed.
・
TAG CHECK
・
MULTI WRITE
・
HEADUP ACTION
*1
・
CARRIER SENSE
*1: Supported by the B-EX4T1-TS25-R V2.2 or later.
5.11.5.1 TAG CHECK
OFF
Error tag detection is not performed. Though a tag is read before
writing data on it, data is always written on the tag whatever data is set
as the header data.
ON (ID)
Error tag detection is performed. A tag (EPC area for GEN2 tags) is
read before writing data on it and data is written on the tag only when
the header data is “A5A5”.
ON
(ACCESS
PASSWORD)
Error tag detection is performed only for GEN2 tags. The access
password area of a tag is read before writing data on it. Only when the
data read matches the access password setting data, the data is
written on the tag.
To prevent unauthorized changes of the setting, a password to protect the error tag detection
setting can be programmed.
Display
Operation
When the TAG CHECK parameter is set to ON (ACCESS PASSWORD)”, an entry of the
password is requested. The following explanation is for when protected password is enabled.
Input the default password “0000” or 4-digit password
programmed in Step 6.
When the password matches, TAG CHECK parameter setting screen appears.
If the entered password does not match, an error message is displayed and the screen returns
to the upper hierarchy menu.
Select a tag check option.
・
Disable
・
Enable (ID)
・
Enable (Password)
When “Disable” or “Enable (ID)” is selected, the password setting is disabled and the screen
returns to the upper hierarchy.
When “Enable (Password)” is selected, the access password entry is requested.
Input 8-digit access password.
Choose whether or not to enable the auto unlock function.
・
OFF
・
ON
When “ON” is selected, locked tags are automatically