![Toshiba B-EX4 SERIES Maintenance Manual Download Page 246](http://html.mh-extra.com/html/toshiba/b-ex4-series/b-ex4-series_maintenance-manual_424322246.webp)
9. MAJOR UNIT REPLACEMENT
EO18-33027
9.6 RIBBON MOTOR SENSORS (TAKE-UP, FEED)
9-12
5) Replace the ribbon motor sensor (take-up) with a new one, then reassemble in the reverse
order of removal. At this time, take care of the following points.
•
Attach the ribbon motor sensor (take-up) to the ribbon sensor plate (take-up) in the correct
direction.
•
Fit the positioning tabs of the ribbon sensor plate (take-up) into the positioning holes in the
ribbon motor mounting plate.
Positioning Tab
Positioning Hole
Ribbon Sensor Plate (Take-up)
Ribbon Motor Mounting Plate