6. ON LINE MODE
EO18-33027
6. 11 LCD MESSAGES AND LED INCATIONS
6-27
Command error
(Refer *1, *2)
while analyzing the command.
21 POWER FAILURE
●
A momentary power interruption
has occurred.
(The LCD message may corrupt
before the error message is
displayed.)
No
No
22 EEPROM ERROR
●
A backup EEPROM cannot be
read/write pr.
No
No
23 SYSTEM ERROR
●
When any abnormal operations as
below are performed, a system error
occurs.
(a) Command fetch from an odd
address
(b) Access to the word data from a
place other than the boundary of
the word data
(c) Access to the long word data from
a place other than the boundary of
the long word data
(d) Access to the area of 80000000H
to FFFFFFFFH in the logic space
in the user system mode.
(e) Undefined command placed in
other than the delay slot has been
decoded.
(f) Undefined command in the delay
slot has been decoded.
(g)
Command to rewrite the delay
slot has been decoded.
No
No
24 DHCP
CLIENT
INIT…
●
●
Initializing DHCP CLIENT.
* Only when DHCP is enabled
---
---
25
RFID WRITE
ERROR
●
The printer did not succeed in
writing data onto the RFID tag
after having retried for the
specified times.
Yes
Yes
26 RFID ERROR
●
The printer cannot communicate
with the RFID module.
No
Yes
27 INPUT PASSWORD ●
●
The printer is waiting for a
password to be entered.
No
No
28 PASSWORD
INVALID
●
●
A wrong password was entered
consecutively for three times.
No
No
29 RFID CONFIG ERR
●
B-EX700-RFID-U2-EU/US-R, B-
EX700-RFID-U4-EU/US-R, U4
module preinstall model only
RFID module’s destination code
is not specified.
No
No
30 LOW BATTERY
(Refer to *4,5)
●
RTC battery is low.
No
Yes
31 INTERNAL COM
ERR
●
●
A hardware error has occurred in
the internal serial interface.
No
No
Explanation of symbols
Symbol
Explanation
Range
:
ON
---