5. SYSTEM MODE
EO18-33027
5.7 SENSOR ADJUSTMENT
5-68
5.7.3 TRANS.
The sensor level of the transmissive sensor is registered.
Remove some labels and place the backing paper so that the Transmissive sensor can detect it.
The display of the currently detected value is updated every 200 msec.
Hold down the [ENTER] key for 3 seconds or more.
When the registration of the “label gap level” is completed, “Adjustment Complete” is displayed and an
asterisk (*) is shown on the right side of the voltage.
If the adjustment failed due to sensor failure, “SENSOR ERROR” is displayed and the ERROR LED
turns on. The ERROR LED turns off when the upper hierarchy menu is displayed.
The setting range is as below.
Transmissive sensor 0.0V
~
5.0 V
5.7.4 PE REFL./TRANS.
Paper end level of the transmissive sensor and the reflective sensor is registered.
Remove any media from the media sensor.
The display of the currently detected value is updated every 200 msec.
Hold down the [ENTER] key for 3 seconds or more.
When the registration of the “paper end level” is completed, “Adjustment Complete” is displayed and an
asterisk (*) is shown on the right side of the voltage.
If the adjustment failed due to sensor failure, “SENSOR ERROR” is displayed and the ERROR LED
turns on. The ERROR LED turns off when the upper hierarchy menu is displayed.
The setting range is as below.
Reflective sensor
0.0V
~
5.0 V
Transmissive sensor 0.0V
~
5.0 V
5.7.5 RIBBON
Ribbon level is registered.
Set the ribbon so that the ribbon end sensor can detect a ribbon area.
The display of the currently detected value is updated every 200 msec.
Hold down the [ENTER] key for 3 seconds or more.
When the registration of the “ribbon level” is completed, “Adjustment Complete” is displayed and an
asterisk (*) is shown on the right side of the voltage.
If the adjustment failed due to sensor failure, “SENSOR ERROR” is displayed and the ERROR LED
turns on. The ERROR LED turns off when the upper hierarchy menu is displayed.
The setting range is as below.
Ribbon end sensor
0.0V to 5.0 V
NOTE: In the case of the B-EX4D2, the status of the ribbon end sensor is always 0.0V.