6. ON LINE MODE
EO18-33027
6. 6 MANUAL THRESHOLD SETTING
6-14
→ The printer enters the user system mode.
4. Select “<2>PARAMETER SET”, “Software Set”, then “THRESHOLD SELECT” with the [UP],
[DOWN] and [ENTER] keys.
5. Select the media sensor type (“REFLECT” or “TRANS.”) depending on the sensor type specified by
the Issue Command, and press the [ENTER] key.
Sensor type in Issue Command
Setting
0: No sensor
Whether the threshold setting succeeded or not cannot be
checked.
1: Reflective sensor
Select “REFLECT”.
When the selected sensor type display is shown, select
“MANUAL SET” and press the [ENTER] key.
* Select the media sensor type to the one for which the
threshold was set.
2: Transmissive sensor (when using
normal labels)
Select “TRANS.”
When the selected sensor type display is shown, select
“MANUAL SET” and press the [ENTER] key.
* Select the media sensor type to the one for which the
threshold was set.
3: Transmissive sensor (when using
preprinted labels)
No setting is necessary.
4: Reflective sensor (when using a
manual threshold value)
No setting is necessary.
6. Press the [MODE] key.
→ User system mode menu is displayed.
7. Select “<1> RESET” and press the [ENTER] key.
→ After the printer is reset, it is placed in the online mode.
8. Send an Issue Command to make the printer print.
→ If a paper jam occurs or the media does not stop at the print start position, retry the threshold
setting.