10. RFID ANALYZE TOOL
EO18-33027
10.4 Operating Procedure
10- 18
Feed amount range (Front/Back Feed)
Set the feed amount range where an RFID tag is analyzed.
Upper limit (Reverse feed amount): 0 – 9990 (in units of 0.1 mm)
Lower limit (Forward feed amount): 0 – 9990 (in units of 0.1 mm)
The values can be entered by either pressing the “UP” or “DOWN” button or directly entering a number.
While the printer feeds RFID tag media in the specified range, it stops feeding at 3-mm intervals and
analyzes the read/write performance of tag.
The number of read/write times (Try)
Enter the number of times a data read/write is performed at each analysis position (1 – 255).
[STOP] button
[End] button
Reverse feed
amount
Forward feed
amount
Try: 1 – 255