Important:
Always keep the battery retainer
in place to protect and secure the battery.
3.
Connect the positive (red) cable to the positive
(+) battery post and the negative (black) cable
to the negative (-) battery post using the bolts
and wing nuts. Slide the rubber boot over the
positive battery post.
4.
Install the battery cover and secure it with the 2
knobs (
).
Checking the Electrolyte Level
Service Interval:
Every 50 hours
Note:
When the machine is in storage check the
battery-electrolyte level every 30 days.
1.
Loosen the knobs on the sides of the battery box
and remove the battery cover (
2.
Remove the filler caps. If the electrolyte is not
up to the fill line, add the required amount of
distilled water; refer to
.
DANGER
Battery electrolyte contains sulfuric acid
which is a deadly poison and causes
severe burns.
•
Do not drink electrolyte or allow it to
contact your skin, eyes or clothing.
Wear safety glasses to shield your
eyes and rubber gloves to protect
your hands.
•
Fill the battery where clean water is
always available for flushing the skin.
Adding Water to the Battery
The best time to add distilled water to the battery is
just before you operate the machine. This lets the
water mix thoroughly with the electrolyte solution.
1.
Clean the top of the battery with a paper towel.
2.
Remove the filler caps from the battery and
slowly fill each cell with distilled water until the
level is up to the fill line. Replace the filler caps.
Important:
Do not overfill the battery.
Electrolyte will overflow onto other parts
of the sprayer and severe corrosion and
deterioration will result.
Charging the Battery
WARNING
Charging the battery produces gasses that
can explode.
Never smoke near the battery and keep sparks
and flames away from battery.
Important:
Always keep the battery fully charged
(1.260 specific gravity). This is especially
important to prevent battery damage when the
temperature is below 0°C (32°F).
1.
Remove the battery from the chassis; refer to
Removing the Battery (page 47)
.
2.
Check the electrolyte level; refer to
the Electrolyte Level (page 48)
.
3.
Connect a 3 to 4 A battery charger to the battery
posts. Charge the battery at a rate of 3 to 4 A
for 4 to 8 hours (12 V).
Important:
Do not overcharge the battery.
4.
Install the battery in the chassis; refer to
Installing the Battery (page 47)
.
Storing the Battery
If the machine will be stored for more than 30 days,
remove the battery and charge it fully. Either store
it on the shelf or on the machine. Leave the cables
disconnected if it is stored on the machine. Store
the battery in a cool atmosphere to avoid quick
deterioration of the charge in the battery. To prevent
the battery from freezing, ensure that it is fully
charged.
48