pressure reading on the gauge is 6.9 bar (100
psi).
g028049
Figure 20
1.
Agitation-bypass valve
2.
Master-section bypass
12.
Press the pump switch to the O
FF
position, shift
the throttle lever to the I
DLE
position, and turn
the ignition switch to the O
FF
position.
Adjusting the
Master-Section-Bypass
Valve
Note:
Adjusting the master-section-bypass valve
reduces or increases the amount of flow sent to the
agitation nozzles in the tank when the master-section
switch is set to the O
FF
position.
1.
Fill the sprayer tank 1/2 full with clean water.
2.
Move the machine to an open level surface.
3.
Set the parking brake.
4.
Set the range selector to the N
EUTRAL
position.
5.
Set the pump switch to the O
N
position.
6.
Set the agitation switch to the O
N
position.
7.
Set the master-section switch to the O
FF
position.
8.
Increase the engine speed to full throttle and set
the throttle lock to the O
N
position.
9.
Adjust the master-section-bypass handle to
control the amount of agitation occurring in the
tank (
).
10.
Reduce the throttle speed to idle.
11.
Set the agitation switch and pump switch to the
O
FF
position.
12.
Shut off the machine.
Locating the Spray Pump
The spray pump is located under the seat (
).
g216323
Figure 21
Hauling the Machine
•
Use full-width ramps for loading the machine onto
a trailer or truck.
•
Tie the machine down securely.
Transporting the Sprayer
When moving the sprayer long distances, use a trailer.
•
Secure the sprayer to the trailer.
– Use the tie-down loop at the front of the frame;
refer to
A.
– Use the 2 tie-down loops at the rear of the
frame; refer to
B.
•
Ensure that the outer-boom sections are tied down
and secure.