Adjusting the Bypass Valves
1.
Using the application-rate switch, adjust the
application rate according to the table below.
Nozzle Color
SI (Metric)
English
Turf
Yellow
159 l/ha
17 gpa
0.39 gpk
Red
319 l/ha
34 gpa
0.78 gpk
Brown
394 l/ha
42 gpa
0.96 gpk
Gray
478 l/ha
51 gpa
1.17 gpk
White
637 l/ha
68 gpa
1.56 gpk
Blue
796 l/ha
85 gpa
1.95 gpk
Green
1,190 l/ha
127 gpa
2.91 gpk
2.
Turn off the left section and adjust the
section-bypass knob (
) until the
pressure reading is at the previously adjusted
level (typically 2.75 bar or 40 psi).
Note:
The numbered indicators on the bypass
knob and needle are for reference only.
g028047
Figure 18
1.
Section-bypass adjustment knobs
3.
Turn on the left section and turn off the right
section.
4.
Adjust the right section-bypass knob (
)
until the pressure reading is at the previously
adjusted level (typically 2.75 bar or 40 psi).
5.
Turn on the right section and turn off the center
section.
6.
Adjust the center section-bypass knob (
) until the pressure reading is at the previously
adjusted level (typically 2.75 bar or 40 psi).
7.
Turn each section off.
8.
Turn the pump off.
Note:
Calibration is now complete.
Agitation-Bypass Valve
Knob Position
•
The agitation-bypass valve is in the full open
position as shown in
•
The agitation-bypass valve is in the closed (0)
position as shown in
•
The agitation-bypass valve is in an intermediate
(adjusted relative to the pressure gauge for the
sprayer system) position as shown in
C.
g214029
Figure 19
1.
Open
3.
Intermediate position
2.
Closed (0)
Calibrating the
Agitation-Bypass Valve
Service Interval:
Yearly
Select an open flat area to perform this procedure.
1.
Fill the spray tank with clean water.
2.
Verify the agitation-control valve is open. If it has
been adjusted, open it completely at this time.
3.
Set the parking brake and start the engine.
4.
Set the range selector to N
EUTRAL
.
5.
Set the pump switch to the O
N
position.
6.
Press the accelerator pedal to achieve maximum
engine speed and set the throttle lock.
7.
Set the 3 section valves to the O
FF
position.
8.
Set the master-section switch to the O
N
position.
9.
Set the system pressure to M
AXIMUM
.
10.
Press the agitation switch to the O
FF
position
and read the pressure gauge.
•
If the reading remains at 6.9 bar (100 psi) the
agitation-bypass valve is properly calibrated.
•
If the pressure gauge reads differently,
continue to the next step.
11.
Adjust the agitation-bypass valve (
)
on the backside of the agitation valve until the
32