Micro-Master Touch User Guide
54
© 2014 Toro Australia Pty Ltd
Ver 1.2, June 2014
10
Single Station Programs
10.1
Overview and Operation
Each Station in the Micro-Master Touch controller can have it's own independent program. Each
Station program can be enabled or disabled. Station programs can be time or volumetric based.
Stations can be assigned Pump Sets, Filter Banks, and Control Inputs, and has it's own Day Table. If
desired, a Station Program can use the same parameters as Station 1.
Station Operation
When a Station program starts, the assigned pump set is also started. If a PreStart Delay has been
set, the Station is not started until the PreStart Delay has expired. When the PreStart Delay
completes, the Station is started for the specified runtime. If the irrigation units are volumetric the
volume units are the same as the allocated Flow Meter. When active, the Station program can be
held by an allocated Hold Input, or held by a keyboard hold. Irrigation will recommence when neither
a keyboard, of control input hold is active. When the runtime is complete, and more than 1 repeat
cycle has been specified, the Station enters a Cycle Delay. When the Cycle Delay expires, the
Station will begin the PreStart Delay (if set), or start the Station. When all repeat cycles have run,
the Station stops.
The station operation is shown in Figure 34.
Idle
PreStart
Delay
Starting
Active
Held by
Input
Stopping
Cycle
Delay
Held by
Key
Hold
off
Input
Hold on
Key
Hold on
Hold
off
more
cycles
Key Hold on
Input Hold on
complete
complete
Delay
complete
Delay
complete
Figure 34 - Single Station Operation Schematic