Irrigation Time is Longer Than
Programmed
Power failure has occurred
during irrigation.
Program Error
A HOLD occurred during
irrigation
Check Runtimes, Water Budget
Check Sensor Reports
Display indicates Irrigation in
Progress but Pumps and
Stations are not switched ON.
Faulty Fuse
Faulty wiring or valves
Replace fuse.
Check wiring and valves.
Display does not start
The Controller has multiple
microprocessors and need to be
synchronized when switching on
Switch off the controller and
remove the standby battery.
Wait 5 seconds and switch on
again.
Table 2 - Fault Finding, Possible Causes
21.4
Diagnostics
The Touch Controller uses various memory technologies to hold the controller firmware, irrigation
programs and data. The diagnostics provides information relating to the health of the controller.
The Diagnostics screen is displayed by pressing the
icon on the Setup Selection screen.
Figure 101 - Controller Diagnostics
Log to USB
If the Log to USB is enabled and a valid USB Flash Drive is connected to the controller, detailed
diagnostic messages will be saved to a file on the USB Flash Drive. If necessary, these diagnostic
messages may assist in isolating problems in the controller.