Testing the CAN bus Terminator Resistors (continued)
resistor and the resistor holder for damage or corrosion and clean or repair
if necessary.
Note:
The insulator wedge in the external termination resistor is blue
for identification purposes. There also is a center keyway to prevent the
termination resistor from plugging into the wrong wire harness connector.
Location
Harness
Connector
Pin
Wire
Color
Expected
Reading
Connector Graphic
1
A
2
CAN bus
Terminator
Resistor
Resistor
at
connector
P35 or
P111
B
N/A
120
ohms
4. If testing determines the external termination resistor is faulty, replace the
resistor.
5. After testing is complete, make sure the external terminator resistor is fully
installed into the connector and secured to the wire harness.
6. Install the operator’s console covers if previously removed.
Internal Resistors
g305815
Figure 105
1.
Yanmar SA-D connector
2.
Cover
1. Park the machine on a level surface, lower the cutting unit (or attachment),
engage the parking brake, set the key switch to the O
FF
position and remove
the key from the key switch.
2. Remove the operator’s console covers; refer to
Operator’s Console Covers (page 7–23)
.
3. Disconnect the external CAN bus terminator resistor from the machine wire
harness at the front of the operator’s console.
Groundsmaster
®
3200, 3300 and 3310
Page 6–57
Electrical System: Testing the Electrical Components
19240SL Rev A
Summary of Contents for Groundmaster 31900
Page 4: ...Reader Comments Page 4 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Page 16: ...Safety Safety and Instructional Decals Page 1 8 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Page 86: ...Engine Service and Repairs Page 4 24 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Page 332: ...Operator Cab Service and Repairs Page 9 18 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Page 355: ......