2
-
4
2.6
Alert list
Alarm
code
Alarm content
Possible cause
"1"
Main power is abnormal When the main power (AC power source) was lost.
"2"
Power is abnormal
When the power supply in the control unit went over-voltage
or over-current.
"3"
Inverter is abnormal
When the inverter in the master compass went over-voltage
or over-current.
"6"
Rotor level abnormally
When the "rotor
”(sensitive element) in the master compass
level abnormally.
"8"
Zero cross is abnormal
When the reference heading of the master compass was not
detected properly or abnormality is generated in heading
calculation.
"A"
System communication
abnormality (1)
When abnormality is generated in communication function of
the master compass.
"b"
System communication
abnormality (2)
When abnormality is generated in communication function of
the control unit.
"c"
GNSS communication
break
When GNSS operation stopped or the serial signal from
GNSS has stopped.
"d"
Abnormality of GNSS
data
When abnormality is generated in the serial signal from
GNSS.
"E"
System internal
communication
abnormality (1)
When the External heading sensor signal processing unit
stopped its operation or the serial signal from the External
heading sensor signal processing unit has stopped.
"F"
System internal
communication
abnormality (2)
When abnormality is generated in the serial signal from the
External heading sensor signal processing unit.
"G"
Master compass
heading abnormality
When abnormality is generated in the heading monitor
signal of the master compass.
"L"
External heading
sensor communication
off
When the External heading sensor signal processing unit
stopped its operation or the serial signal of the external
sensor has stopped.
"n"
External heading
Sensor data
abnormality
When abnormality is generated in the serial signal from the
External heading sensor.
"P"
LOG (serial)
communication off
When the LOG stopped its operation or the serial signal
from LOG has stopped.
"r"
E5V abnormality
When abnormality is generated in the power supply for the
serial signal.
"U"
LOG (serial) data
abnormality
When abnormality is generated in the serial signal from
LOG.
"u"
LOG contact
abnormality
When abnormality is generated in the LOG contact.
Summary of Contents for TG-8000 Series
Page 2: ......
Page 20: ...18 blank...
Page 26: ...1 6 blank...
Page 60: ...3 28 blank...
Page 84: ...6 2 blank...
Page 86: ...7 2 CONTROL UNIT OPERATING UNIT Fig 7 1 Outline of control unit One Gyro compass system...
Page 88: ...7 4 Fig 7 3 Master compass FUSE F1 12A...
Page 96: ...7 12 Power Supply Unit Fig 7 11 Power Supply Unit...
Page 98: ...7 14 blank...
Page 104: ......