8
8-5
TLDI 115A 2007
4) Inspection of Pinion
1.
Check pinion teeth for nick and wear.
Replace if necessary.
a
3) Inspection of Brushes
1.
Measure brush length
a
, and replace brush if the length is
less than specified value.
2
3
4
5
1
2.
Check conductivity between brush and starter terminal.
Replace brush ass'y if any of the following conditions is
met.
Between Brush and
2
-
4
Conductive
Brush
3
-
4
Between Brush and
2
-
5
Conductive
Motor Base
3
-
5
Between Brush and
2
-
1
No Conductivity
Starter Motor Terminal
3
-
1
Between Brush and
4
-
5
No Conductivity
Motor Base
Brush Length
a
: Standard Value
14 - 15 mm (0.55 - 0.59 in)
Wear Limit :
12 mm (0.47 in)
MD115A̲ch08̲E̲2校̲070604.qxd 07.6.6 6:38 PM ページ 5