![TOHATSU TLDI MD 115A SERIES Service Manual Download Page 214](http://html1.mh-extra.com/html/tohatsu/tldi-md-115a-series/tldi-md-115a-series_service-manual_1124699214.webp)
6-36
Lower Unit
TLDI 115A 2007
6.
Attach O ring
w
to pump case (lower)
q
and install pump
case (lower) to gear case.
q
w
GREASE
OBM
OBM
OBM
CAUTION
Align pump liner
i
protrusion
a
with pump
case (upper)
o
concave
b
.
10.
Put pump case (upper)
o
and pump case seal
p
on the
drive shaft, and install them on the pump case (lower)
q
.
CAUTION
While installing pump case
o
, turn drive
shaft
4
clockwise to bend all impeller
blades in counterclockwise direction.
11. Attach water pipe seal
a
(RP).
y
u
4
o
i
b
a
Inner
Face
GREASE
OBM
OBM
OBM
4
o
c
q
9.
Attach water pump liner
i
to pump case (upper)
o
.
7.
Put dowel pin
e
on the pump case (lower)
q
, and attach
pump case guide plate gasket
r
and pump case guide
plate
t
.
8.
Attach water pump impeller key
y
to drive shaft
4
, align
the key with the water pump impeller
u
side key groove,
and install the impeller.
Apply OBM grease to O ring.
Apply OBM grease to inside of water pump
liner.
Apply OBM grease thinly on the inside
c
of
water pipe seal so that water pipe can be
inserted smoothly.
MD115A̲ch06̲E̲2校̲070604.qxd 07.6.6 6:34 PM ページ 36