Operating instructions
44
As of 06/13
The signal detection in combination with a corresponding Stopp time
can also be used for switching off. Once the Stopp time has expired,
the yellow Info-LED flashes and the shutdown gets started. This
process can not be interrupted.
In all operation modes the display device is switched off by means of
infrared sequence or RS232 command. The relevant switch off and
safety times are being considered, of course. During the shut down
the Info LED flashes.
C 7
– 9 N.N.
C 10 Options
C 10.1 Expansion of TLS QuickScout Digital AD XL by further
participants
For the use of
TLS QuickScout A/D XL
with
more than 4
participants, you can expand it to a complete system by using further
TLS
QuickScout AD, TLS QuickScout A
and
TLS QuickScout D.
You can combine several analogue connections and several digital
connections in one system. If you are planning the installation of a
larger
QuickScout
system, possibly with partitions, you should
contact the technical support ([email protected]), to
check further technical details.
To interconnect the relative
TLS QuickScout
modules,
plug a TLS DVI connection cable (male/male) into the DVI
input provided
BUS IN
(Sketch 2) of the first module.
Now connect the other side of the DVI connection cable with
the DVI output
BUS OUT
(Sketch 2) of the second module.
Now connect all other modules in the same order, in which
each output of a module has to be connected to the input of the
next module.