Operating instructions
As of 06/13
27
To avoid this kind of problems, it is therefore recommended anyway
to use high-quality
TLS cables
,
not only to enable the EDID
communication, but also to guarantee highest transmission quality.
EDID direct connection
In this operation mode a permanent EDID connection between signal
source and display device is provided. This operation mode is
required e. g. to ensure permanent communication in the HDMI
operation with HDCP. Thus a permanent exchange of the HDCP
keys is possible. Also recent VGA signal sources require in part this
option, as they have to communicate permanently with the display
device, too and then also have to resend instantly while switching.
Enable HPD reset HDMI 1
– 2
(HPD = Hot Plug Detect)
In this operation mode by selecting HDM1 respectively HDMI2 of the
signal source a control signal corresponding to Hot-Plugging is
transmitted to the display device. Hereupon the communication from
the signal source with the display device starts. The control signal
transmitted initiates e. g. the switching on of the display device
Anzeigegerätes from standby mode.
Enable always read DDC
In this operation mode in the communication between signal source
and display device always the complete data set is read and
processed. However mostly a shortened form of this data set is
already sufficient for the communication, so that this operation mode
can be deactivated. Thus the switching wird der switching procedure
even quicker.
Toggle VGA 1 / HDMI 1 (VGA2 / HDMI2)
This operation mode allows for a
„2 button operation mode“ of the
TLS QuickScout A/D XL
. The inputs VGA1/HDMI1 and
VGA2/HDMI2 are summarised each to a group and thus seem to be
connected. Now each on IN1 of the VGA side and on IN1 of the
HDMI side an external button has to be connected.