Operating instructions
As of 06/13
33
XL Settings
– Output settings
ON:
Output 1
OFF:
Output 2
DOWN:
Output 3
UP:
Output 4
At this point the characteristics of the 4 outputs are defined. The
timings are entered in seconds in the operation mode
„activate for
time x“. In addition every output can assume the operation modes
„activate“ or „release“.
The outputs 1 and 3 as well as 2 and 4 in addition are coupled. In
that way in practice pressing the button 1 will switch on the system
and afterwards will lower the screen with output 3. The same way
pressing the button 2 will switch off the system and afterwards run up
the screen.
Warning: If the inputs 1 and 2 are used for switching on and off,
or a key switch is used, these inputs will have no further
function.
Otherwise
the point “Don´t use external inputs to switch ON/OFF
the system“ in the settings above must be selected.
C 5.2.1.3 Key Commands
In this menu item you can learn the IR-Codes, repectively enter the
RS232 codes, which are used to control the display device.
Key 1 and key 2 are used to control the switching on/off function of
the display device, key 3 and Key 4 activate, depending on the
system status, or the analogue input or the digital input of the display
device.