Operating instructions
26
As of 06/13
EDID mode
This column is used configure the EDID and DDC operation modes.
EDID locked mode
In this operation mode the EDID data set of the display device is
stored in the memory of the
TLS QuickScout A/D XL
and is
displayed constantly to all signal sources. In this way the signal
output of every connected signal sources remains active, although
another input channel has been selected. If to another source will be
switched, this source is able to send instantly.
Furthermore this
operation mode enables to respond also to
inadequate
connection cables to the display device, which might be technically
not able to guarantee an EDID communication the display device. At
the begin of the installation the
TLS QuickScout A/D XL
has to be
connected once only with a TLS cable to the display device.
Hereupon the
TLS QuickScout A/D XL
can save the EDID data set
and store it permanently in the device memory. Now the signal
sources access this data set and send hereupon a signal to the
display device.