Line Adapter
instructions on page 21. Read each step completely before performing the
instruction.
Removing an Unused CO2 Cartridge (Non-Punctured)
1. Put the trigger safety in the Safe mode (see page 6) and install the barrel blocking
device (see page 4).
2. Press the Magazine Release button (4) and the Magazine (79) ejects out of the grip.
NOTE: When removing a loaded Magazine from the marker, two loose paintballs might
drop from the grip. Pull the Magazine’s Ball Carrier down until it locks to take pressure
off the paintballs, and reload any loose paintballs into the Magazine.
3. Keep the marker pointed in a safe direction, and remove the CO2 Cap (15).
a. Push in and turn the CO2 Cap counterclockwise until it stops. Then pull out until it
stops to partially unscrew the cap. NOTE: The cap should be easy to turn; if you
are unable to turn it, or if it is difficult to turn, the cartridge has been punctured
and you must follow the instructions below,
Removing a Used CO2 Cartridge
(Punctured)
.
b. Turn the CO2 Cap a second turn counterclockwise until it stops and pull it out. The
CO2 cartridge will then slide out.
4. Replace the CO2 Cap. Align the cap pins with the pin guides of the Cap Receiver
Insert (14). Push the cap in and turn clockwise. Push the cap in a second time and turn
clockwise.
Removing a Used CO2 Cartridge (Punctured)
NOTE: A punctured CO2 cartridge must be emptied before it is removed.
1. Put the trigger safety in Safe mode (see page 6) and install the barrel blocking device
(see page 4).
2. Press the Magazine release button (4) and the Magazine (79) ejects out of the grip.
NOTE: When removing a loaded Magazine from the marker, two loose paintballs might
drop from the grip. Push the Magazine’s Ball Carrier down until it locks to take pressure
off the paintballs, and reload any loose paintballs into the Magazine.
3. Go to a designated firing area and remove the barrel blocking device.
4. Point the marker in a safe direction, move the trigger safety to Fire mode, and fire
until there is no CO2 left in the cartridge. NOTE: If you have a punctured cartridge in
your marker and the marker will not fire, follow the instructions on page 17,
Release
Pressure From a Marker That Will Not Fire
.
5. Put the trigger safety in Safe mode (see page 6) and install the barrel blocking device
(see page 4).
6. Visually inspect the chamber for paintballs through the Magazine opening at the bottom
of the grip.
7. Keep the marker pointed in a safe direction during CO2 Cap removal.
a. Keep exposed skin away from escaping CO2 - the arrows in the WARNING
illustration on page 10 show CO2 escape points. Push in and turn the CO2 Cap
slowly counterclockwise until it stops, and pull until it stops to partially unscrew the
cap, then wait as any remaining CO2 in the cartridge escapes before performing
step (b) (keep exposed skin away from escaping CO2).
b. Turn the CO2 Cap a second turn counterclockwise until it stops and pull it out. The
empty cartridge then slides out.
8. Replace the CO2 Cap by aligning the CO2 Cap pins with the pin guides of the Cap
Receiver Insert (14) and pushing the Cap in while turning clockwise. Push the Cap in a
second time, turn clockwise, and release.