Interfaces
6-29
Installation Manual for Models ODM-005, ODM-005i, ODM-010, ODM-010i, ODM-020 and ODM-020i
Factory default settings for a OMNIDRIVE are:
•
Address 0
•
9600 Baud
•
8 Data, No Parity, 1 Stop bit
The following steps outline how to select the communications options:
1. Connect an RS-232 cable between the computer and a serial connector on the drive (J5).
2. Verify the computer can communicate with the drive by performing the following:
•
Switch drive power to ON
•
Start OMNI LINK on the attached PC
•
Choose
CANCEL
from the Drive Select window
•
Select
Communications
from the menu
•
Select
PC Set Up
from the pull down menu
•
Verify the port settings, and if necessary, change them, then choose
OK
.
•
Select
Communications
from the menu
•
Select
Read Drive Parameters
from the pull down menu
•
Choose
OK
in the Drive Select window.
3. Verify that OMNI LINK reads the drive parameters. If not, refer to “Troubleshooting” on
page 11-3.
Intro
F
IGURE
6.39
RS-232 Connection Diagrams
USER
2
9-Pin
Drive
2
Drive Chassis
PC
3
3
5
Male
RS-232 CABLE
J4 or J5
2
3
5
RCV
XMT
COM
RCV*
XMT*
COM*
* PC pin-outs
may vary by
manufacturer
9-Pin
Female
9-Pin Male Connector to 9-Pin Female Connector
9-Pin
RS-232
USER
2
9-Pin
Drive
2
Drive Chassis
PC
3
3
5
7
Male
RS-232 CABLE
J4 or J5
2
3
5
RCV
XMT
COM
XMT*
RCV*
COM*
* PC pin-outs
may vary by
manufacturer
25-Pin
Female
9-Pin Male Connector to 25-Pin Female Connector
25-Pin
RS-232
5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com