Application and Configuration Examples
8-23
Installation Manual for Models ODM-005, ODM-005i, ODM-010, ODM-010i, ODM-020 and ODM-020i
display codes.
2. Start OMNI LINK on the PC.
3. Choose
Cancel
from the Drive Select dialog box.
4. Select
PC Set Up
from the Communications menu in OMNI LINK to display the personal com-
puter’s communication settings.
5. Verify the communications port settings of the PC match those of the drive.
•
If the settings are correct, select
OK
in the Port – Settings dialog box.
•
If the settings are different, correct the Port – Settings to allow communications with the
drive.
Factory default communications Port – Settings for the drive are:
– Baud Rate:
9600
– Data Bits:
8
– Parity:
None
– Stop Bits:
1
– Serial Port:
COM1
Refer to the section “RS-232 Communication Test” on page 11-6 for troubleshooting instructions.
6. Select
Read Drive Parameters
from the Communications menu.
7. Verify the Drive Name and Address are correct for the drive that is being addressed.
8. Choose
OK
to load the drive parameters.
9. If the message box appears that a motor must be selected, select
OK
. The Drive Setup window is
displayed with Motor Model selection parameter active. The motor may be selected from the
drop down box. If this message box does not appear, the motor displayed in the Motor Model
box was previously selected.
10. Select or verify the correct motor model number from the drop down Motor Model list.
11. If a message advises that the drive must be reset, choose
Yes
.
12. Select
Indexing
as the Operation Mode for the drive.
13. Choose
Close
to exit the Drive Set Up window.
14. Choose the
Drive Parameters
command icon from the Drive window and then select the
Indexing tab
.
15. Enter the following values for Index 0. Refer to “Incremental Indexing Examples” on page 8-21
for examples of Single and Batched Incremental Indexing profiles.
TIP
A motor must be selected for the parameters to load.
Single Move Settings
Batched Move Settings
Incremental
as Mode
Incremental as Mode
8000
as Distance
8000 as Distance
1
as the Batch Count
3
as the Batch Count
0
as Dwell
1000
as Dwell
Appropriate values for Acceleration and Decelera-
tion
Appropriate values for Acceleration and Decelera-
tion
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com