A-8
TouchPad Instructions
• The TouchPad displays
Fault
and a description. A Fault message requires additional trouble-
shooting of the drive.
Clear the fault display by depressing the and keys simultaneously.
Fault codes are stored in the TouchPad parameter
DrvStat
and are explained with trouble-
shooting guidelines in Table 11.1 on page 11-3.
• The TouchPad alternately displays
Error
and the error name. Clear an error by pressing the
key.
• The TouchPad momentarily displays and then clears a warning when an invalid entry is
made.
TouchPad Options
T
ABLE
A.1
TouchPad Fault/Error/Warning Displays
Display
Level
Description
BufOvFlo
Error
Communications buffer overflowed.
Can’tDo
Error
An invalid function type encountered in the TouchPad data table. The Touch-
Pad data table is incorrect for the drive.
Checksum
Error
The checksum of the command is in error. Information is corrupted.
CmdNoEnb
Error
The command is not enabled.
DataDisp
Warning
The parameter is a live data display and cannot be modified.
DrvEnabl
Warning
The parameter cannot be changed while the drive is enabled.
Fault
Fault
Drive fault detected.
InvlData
Warning
Invalid data was entered for the parameter.
InvldFn
Error
Illegal function code received by drive. The TouchPad data table is incorrect for
the drive.
InvldRsp
Error
Invalid Response received from drive. Received code did not match transmitted
code.
Lower Lim
Warning
The lower limit of the parameter has been reached.
NoMemory
Error
TouchPad memory has been exhausted.
NoRetSel
Warning
Mode/Enter key incorrectly pressed.
OverRng
Error
Value from drive is too large to display.
RAMWrite
Error
An error was detected while writing the drive’s parameter memory.
ReadOnly
Warning
The parameter is Read Only and cannot be modified.
Timeout
Error
The communications port timed out.
UnxpChar
Error
The communications port received an unexpected character.
UpperLim
Warning
The upper limit of the parameter has been reached.
T
ABLE
A.2
Option Selections for the TouchPad
DRVPARM
TUNING
Parameter
Options
Parameter
Options
AccelEn
Enable/Disable
SWEnable
Enable/Disable
SlewEnab
Enable/Disable
I OverRd
Enable/Disable
STATUS
CTLPANEL
Parameter
Options
Parameter
Options
SWEnable
Enable/Disable
SWEnable
Enable/Disable
EncAlign
Normal/Align
Start
Normal/CtlPanel
RmvOfst
to Rmv
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com