Overview
The IntelliTrack™ XR (IXR) function is an intelligent software-driven solution to two
common problems that occur when trying to detect contaminants.
•
Wet products where you are trying to detect non-magnetic stainless steel.
•
Products that produce inconsistent phase angles from package to package, or
within a single pack itself.
Before proceeding, please make sure the APEX and its associated operating environment
and the product you are running, meet the following requirements.
System Requirements
The APEX and its associated operating environment must meet the following
requirements.
•
An in-feed product photo eye is installed.
•
The in-feed product photo eye is positioned as follows;
o
at least 1x (one times) the smallest dimension of the search head’s
aperture, and,
o
no more than 5x this dimension from the in-feed edge of the aperture.
•
In-feed guide rails are installed to prevent the packaged product from skewing.
•
The conveyors are always run at a constant speed during your normal production
runs and during the IXR calibration process. (Please note that, if—at a later
date—you change the speed of the conveyor on your normal production runs, the
IXR function must be recalibrated.)
•
Version 4.0.0 (or later) of the detector’s operating software is installed.
Product Requirements
The product you are running must meet the following requirements.
•
The product must be in package form. Please note, the IXR function should not
be used for bulk products on conveyors (for example, apples, grapes, and so on)
or on liquids in pipelines.
•
The leading edge of the packed product must consistently block the in-feed photo
eye. This requirement is critical for the IXR function to work properly.
•
The packaged product must not skew as it passes through the search head. This
requirement is also critical for the IXR function to work properly.
•
When using the IXR calibration functions, a minimum gap between the packages
equal to the width of the search head is required.
•
During normal production runs, a minimum gap of 25 mm between packages
must be maintained. (Please note that if the APEX detects no gap between the
packages, the IXR function will use the package length you entered, but false
rejects may occur as a result.)
Summary of Contents for APEX 100
Page 1: ...Thermo Scientific APEX Metal Detector User s Guide REC 4248 Rev K Part number 085381 English ...
Page 10: ...Page 10 Thermo Scientific APEX User s Guide ...
Page 78: ...Page 78 Thermo Scientific APEX User s Guide ...
Page 110: ...Page 110 Thermo Scientific APEX User s Guide ...
Page 258: ...Page 258 Thermo Scientific APEX User s Guide ...
Page 270: ...Page 270 Thermo Scientific APEX User s Guide ...
Page 282: ...Page 282 Thermo Scientific APEX User s Guide ...
Page 310: ...Page 310 Thermo Scientific APEX User s Guide ...
Page 319: ...Thermo Scientific APEX User s Guide Page 319 Appendix A Modbus Communications Card ...
Page 320: ...Page 320 Thermo Scientific APEX User s Guide ...
Page 324: ...Page 324 Thermo Scientific APEX User s Guide ...
Page 340: ...Page 340 Thermo Scientific APEX User s Guide ...
Page 367: ...Thermo Scientific APEX User s Guide Page 367 Appendix B IntelliTrack XR ...
Page 368: ...Page 368 Thermo Scientific APEX User s Guide ...
Page 402: ...Page 402 Thermo Scientific APEX User s Guide ...
Page 404: ...This page intentionally left blank ...
Page 414: ...This page intentionally left blank ...
Page 430: ......
Page 431: ......
Page 432: ......
Page 433: ......
Page 434: ......
Page 435: ......
Page 436: ......
Page 437: ......
Page 438: ......
Page 439: ......
Page 440: ......
Page 441: ......
Page 442: ......