Thermo Scientific APEX User’s Guide
Page 355
For example, if register 30021 contains the value “0x0123” and register 30022 contains
the value “0x4567”, the total reject count is calculated as follows.
Register
value
Mathematical
expression
Numeric
value
0x0123
0 x 16
7
=
0
0x4567
+1 x 16
6
=
16,777,216
+2 x 16
5
=
2,097,152
+3 x 16
4
=
196,608
+4 x 16
3
=
16,384
+5 x 16
2
=
1,280
+6 x 16
1
=
96
+7 x 16
0
=
7
Total =
19,088,743
This, clearly, is an unrealistically high total reject count, but illustrates how register
values are used to assign a numeric value for the total number of rejects.
Resetting Statistics
To reset the following APEX statistics, set parameter-change coil 16386 to one (1). This
resets the following APEX statistics—and the appropriate Modbus registers listed below—
to zero (0).
•
Total reject count
•
Quality Assurance Test count
•
AuditCheck count
•
Total pack count
Resetting Peak Values
To reset the APEX peak values, set parameter-change coil 16388 to one (1). This resets
the current peak value to zero (0).
Backing Up Critical APEX Settings
Backing up critical APEX data is important, because it provides insurance against
catastrophic system failures. Backing up your data does not take up a lot of space. The
amount of disk space needed to back up a single product, for example, is only 808
bytes, as shown in the table below.
NVRAM allocation
Space used (bytes)
DSP configuration
96
HMI configuration
388
Single-product configuration 324
Total =
808
See glossary for explanation of acronyms
Summary of Contents for APEX 100
Page 1: ...Thermo Scientific APEX Metal Detector User s Guide REC 4248 Rev K Part number 085381 English ...
Page 10: ...Page 10 Thermo Scientific APEX User s Guide ...
Page 78: ...Page 78 Thermo Scientific APEX User s Guide ...
Page 110: ...Page 110 Thermo Scientific APEX User s Guide ...
Page 258: ...Page 258 Thermo Scientific APEX User s Guide ...
Page 270: ...Page 270 Thermo Scientific APEX User s Guide ...
Page 282: ...Page 282 Thermo Scientific APEX User s Guide ...
Page 310: ...Page 310 Thermo Scientific APEX User s Guide ...
Page 319: ...Thermo Scientific APEX User s Guide Page 319 Appendix A Modbus Communications Card ...
Page 320: ...Page 320 Thermo Scientific APEX User s Guide ...
Page 324: ...Page 324 Thermo Scientific APEX User s Guide ...
Page 340: ...Page 340 Thermo Scientific APEX User s Guide ...
Page 367: ...Thermo Scientific APEX User s Guide Page 367 Appendix B IntelliTrack XR ...
Page 368: ...Page 368 Thermo Scientific APEX User s Guide ...
Page 402: ...Page 402 Thermo Scientific APEX User s Guide ...
Page 404: ...This page intentionally left blank ...
Page 414: ...This page intentionally left blank ...
Page 430: ......
Page 431: ......
Page 432: ......
Page 433: ......
Page 434: ......
Page 435: ......
Page 436: ......
Page 437: ......
Page 438: ......
Page 439: ......
Page 440: ......
Page 441: ......
Page 442: ......